Tag Reader

Version : Two versions are available.

One for horizontal-mounting, where the display is readable when the card-opening is horizontal. Notice the tiny yellow line around the display, this should be to the lower-right of the display. One for vertical-mounting, where the display is readable when the card-opening is vertical. Notice the tiny yellow line around the display, this should be to the lower-right of the display.

Vertical Horizontal


Switches & ledís :

From left to right, seen from the back of the reader, youíll find :

  • A push-button switch : SERVICE-switch. This transmits the ID-number of the node.
  • A yellow led : SERVICE-led. Lights up when you push the service-switch. When this led flashes or is lit continuously, a severe software problem occurred in the node. ( call us )
  • A red led : TRANSMIT-led
  • A second red led : RECEIVE-led

There are two identical 6-way connectors at the back of the reader. One for horizontal-mounting, the other for vertical-mounting.

pin 1+12V (input)
pin 2GND
pin 3NC
pin 4Network A
pin 5Earth ( shielding )
pin 6Network B

The 12V can be obtained from nodes with these outputs, such as a pneumatic beer valve controller or a post-mix controller.