edit · history · print

Main.InputNode History

Hide minor edits - Show changes to markup

June 08, 2010, at 09:11 AM by 81.188.94.80 -
Changed lines 84-85 from:
  • Flag 13 is only supported in 24-in nodes with software version 2.1 or higher. (Make sure you use Dino version 28.29 or higher)
to:
  • Flag 13 is only supported in 24-in nodes with software version 2.1 or higher. (Make sure you use Dino version 28.30 or higher)
June 07, 2010, at 04:17 PM by 81.188.94.80 -
Changed lines 84-85 from:
  • Flag 13 is only supported in 24-in nodes with software version 2.1 or higher.
to:
  • Flag 13 is only supported in 24-in nodes with software version 2.1 or higher. (Make sure you use Dino version 28.29 or higher)
May 31, 2010, at 11:33 AM by 81.188.94.80 -
Changed line 76 from:
  • 13: Freeflow count: 24-in will count the time an input is active.
to:
  • 13: Freeflow count: 24-in will count the time an input is active. There will only bee a tap action when the flow counter exceeds the calibration value. The rest of the flow counter will be buffered.
May 31, 2010, at 11:22 AM by 81.188.94.80 -
Added line 76:
  • 13: Freeflow count: 24-in will count the time an input is active.
Changed lines 83-84 from:
  • Flags 9 to 12 are only possible in 24-in nodes with software version 2.0 or higher.
to:
  • Flags 9 to 12 are only possible in 24-in nodes with software version 2.0 or higher.
  • Flag 13 is only supported in 24-in nodes with software version 2.1 or higher.
September 08, 2009, at 03:25 PM by 81.188.94.80 -
Changed line 73 from:
  • 10: Binary Invert: same like flag 9, but the inputs and output 3 and 4 are inverted.
to:
  • 10: Inverted Binary: same like flag 9, but the inputs and output 3 and 4 are inverted.
Changed line 75 from:
  • 12: Inverted Debit-Credit: combination of flag 7 and 10.
to:
  • 12: Inverted Debit-Credit Binary: combination of flag 7 and 10.
September 08, 2009, at 03:16 PM by 81.188.94.80 -
Changed lines 61-70 from:
  • 0 = normal action and (soft flow) hall sensor beer valve
  • 1 = inverted all inputs
  • 2 = inverted contact output 3 & 4
  • 3 = inverted all inputs + inverted contact output 3 & 4
  • 4 = engolit non drip invert inputs line 3
  • 5 = Inverted engolit non drip
  • 6 = output becomes active (for 500 ms) after receiving a puls on the input (Debit-Credit mode)
  • 7 = same as "6" but inputs are inverted, output 1&2 are normal, 3 & 4 are inverted (Debit-Credit mode)
  • 8 = tourniquet, output stays 1 sec active after recognition card
to:
  • 1: All inputs work inverted.
  • 2: Output 3 and 4 work inverted (NC).
  • 3: Combination of flag 1 and 2.
  • 4: Engolit non-drip (max 8 connections):
    • Line 1-4-7-10-13-16-19 and 22 are the inputs
    • Line 2-5-8-11-14-17-20 and 23 detects that the Engolit non-drip is present.
    • Line 3-6-9-12-15-18-21 and 24 detects that the Engolit non-drip is removed.
  • 5: Inverted Engolit non-drip.
  • 6: Debit-Credit: output becomes active (for 500ms) after receiving a pulse on the input.
  • 7: Inverted Debit-Credit: same like flag 6, but the inputs and output 3 and 4 are inverted.
  • 8: Tourniquet: output stays 1s active after recognition of a valid card in the reader.
  • 9: Binary: the 24-in reads the 5 first inputs as binary and makes from this combination a product number. ex: input 1, 2 and 5 are active: this gives the binary number: '10011' and resembles product 19. If the number outruns the 24 the input is rejected.
  • 10: Binary Invert: same like flag 9, but the inputs and output 3 and 4 are inverted.
  • 11: Debit-Credit Binary: combination of flag 6 and 9.
  • 12: Inverted Debit-Credit: combination of flag 7 and 10.
  • Not set: Normal functioning of the 24-in

http://wiki.etcworld.be/uploads/Main/24-in_Settings.jpg

Changed lines 81-82 from:
  • In 24-in nodes with version 1.9 or higher there is a support for Credit cards in Debit-Credit mode (Make sure you use Dino version 22.93 or higher)
to:
  • In 24-in nodes with software version 1.9 or higher there is a support for Credit cards in Debit-Credit mode (Make sure you use Dino version 22.93 or higher)
  • Flags 9 to 12 are only possible in 24-in nodes with software version 2.0 or higher.
September 25, 2008, at 10:50 AM by 81.188.94.80 -
Deleted line 71:
  • Flag 6 & 7 are only supported on 24-in nodes with version 1.8 or higher
September 22, 2008, at 03:47 PM by 81.188.94.80 -
Changed lines 5-8 from:

INPUT-node (24/4) ''' Switches & ledís''' :

to:

Switches & ledís :

April 11, 2008, at 03:30 PM by 81.188.94.80 -
Changed lines 75-76 from:
  • In 24-in nodes with version 1.9 or higher there is a support for Credit cards in Debit-Credit mode
to:
  • In 24-in nodes with version 1.9 or higher there is a support for Credit cards in Debit-Credit mode (Make sure you use Dino version 22.93 or higher)
April 11, 2008, at 09:32 AM by 81.188.94.80 -
Changed line 11 from:
  • A yellow led : SERVICE-led. Lights-up when you push the service-switch. When this led flashes or is lit continuously, there is a severe soft-ware problem occurred in the node. ( call us )
to:
  • A yellow led : SERVICE-led. Lights up when you push the service-switch. When this led flashes or is lit continuously, a severe software problem occurred in the node. ( call us )
Changed line 78 from:
  • If you don't wonít that the costumer gets with its account below zero, uncheck the 'N32Vip' in the Dino settings!
to:
  • If you don't want the costumer to go below zero on his account, uncheck the 'N32Vip' in the Dino settings!
April 03, 2008, at 09:26 AM by 81.188.94.80 -
Added lines 76-79:

Setting Credit mode in Dino:

  • If you don't wonít that the costumer gets with its account below zero, uncheck the 'N32Vip' in the Dino settings!
  • Give the product a price.
April 03, 2008, at 08:22 AM by 81.188.94.80 -
Changed lines 69-70 from:
  • 6 = output becomes active (for 500 ms) after receiving a puls on the input
  • 7 = same as "6" but inputs are inverted, output 1&2 are normal, 3 & 4 are inverted
to:
  • 6 = output becomes active (for 500 ms) after receiving a puls on the input (Debit-Credit mode)
  • 7 = same as "6" but inputs are inverted, output 1&2 are normal, 3 & 4 are inverted (Debit-Credit mode)
Changed lines 73-75 from:

WARNING: Flag 6 & 7 are only supported on 24-in nodes with version 1.8 or higher

to:

WARNING:

  • Flag 6 & 7 are only supported on 24-in nodes with version 1.8 or higher
  • In 24-in nodes with version 1.9 or higher there is a support for Credit cards in Debit-Credit mode
July 11, 2007, at 01:41 PM by 81.188.94.80 -
Changed line 73 from:

WARNING: Flag 6 & 7 are only supporten on 24-in nodes with version 1.8 or higher

to:

WARNING: Flag 6 & 7 are only supported on 24-in nodes with version 1.8 or higher

July 11, 2007, at 01:41 PM by 81.188.94.80 -
Changed line 73 from:
to:

WARNING: Flag 6 & 7 are only supporten on 24-in nodes with version 1.8 or higher

July 11, 2007, at 11:13 AM by 81.188.94.80 -
Changed line 70 from:
  • 7 = same as "6" but inputs are inverted, output 1&2 are normal, 3 & 4 are invers
to:
  • 7 = same as "6" but inputs are inverted, output 1&2 are normal, 3 & 4 are inverted
July 11, 2007, at 11:13 AM by 81.188.94.80 -
Added line 66:
  • 3 = inverted all inputs + inverted contact output 3 & 4
July 11, 2007, at 11:10 AM by 81.188.94.80 -
Changed lines 68-72 from:
to:
  • 6 = output becomes active (for 500 ms) after receiving a puls on the input
  • 7 = same as "6" but inputs are inverted, output 1&2 are normal, 3 & 4 are invers
  • 8 = tourniquet, output stays 1 sec active after recognition card
April 20, 2007, at 01:20 PM by 81.188.94.80 -
Changed line 53 from:

http://wiki.etcworld.be/uploads/Main/24-4%2036-pol%20input.jpg

to:

http://wiki.etcworld.be/uploads/Main/24-4%2036-pol%20input.jpg

April 19, 2007, at 11:39 AM by 81.188.94.80 -
Changed lines 62-64 from:

Flags =

  • 0=normal action and (soft flow) hall sensor beer valve
  • 1= inverted all inputs
to:

Flags:

  • 0 = normal action and (soft flow) hall sensor beer valve
  • 1 = inverted all inputs
Changed lines 66-68 from:
  • 4 =engolit non drip invert inputs line 3
  • 5 =Inverted engolit non drip
to:
  • 4 = engolit non drip invert inputs line 3
  • 5 = Inverted engolit non drip
May 08, 2006, at 02:35 PM by 81.188.94.80 -
May 08, 2006, at 01:47 PM by 81.188.94.80 -
Changed lines 67-68 from:
to:
  • 5 =Inverted engolit non drip
May 08, 2006, at 01:45 PM by 81.188.94.80 -
Added lines 58-59:

http://wiki.etcworld.be/uploads/Main/24-4%20Case.jpg

May 08, 2006, at 01:43 PM by 81.188.94.80 -
Added lines 53-57:

http://wiki.etcworld.be/uploads/Main/24-4%2036-pol%20input.jpg http://wiki.etcworld.be/uploads/Main/24-4%2036-pol%20input%20Connections.jpg


May 08, 2006, at 01:42 PM by 81.188.94.80 -
Added lines 31-32:

http://wiki.etcworld.be/uploads/Main/6wayconnector.jpg

April 24, 2006, at 02:56 PM by 81.188.94.80 -
Changed lines 31-32 from:

The 36-way connector.

to:

The 36-way connector.

April 24, 2006, at 02:55 PM by 81.188.94.80 -
Changed line 22 from:
pin 1+12V (output)
to:
pin 1+12V (input)
Changed lines 27-59 from:
pin 6Network B
to:
pin 6Network B

The 12V can be obtained from nodes with these outputs, such as pneumatic beer valve controller or post-mix controller, or from a separate supply.

The 36-way connector.

pin 1,10,19input 1.1/1.2/1.3
pin 2,11,20input 2.1/2.2/2.3
pin 3,12,21input 3.1/3.2/3.3
pin 4,13,22input 4.1/4.2/4.3
pin 5,14,23input 5.1/5.2/5.3
pin 6,15,24input 6.1/6.2/6.3
pin 7,16,25input 7.1/7.2/7.3
pin 8,17,26input 8.1/8.2/8.3
pin 9, 18+12Vdc common for input switches
pin 27, 36GND
pin 28-29NO contact 1
pin 30-31NO contact 2
pin 32-33NO contact 3 / NC contact when flags = 2
pin 34-35NO contact 4 / NC contact when flags = 2

Contact 1 to 4 are closed simultaneously when a valid card is in the reader. These contact are electrical independent so they can enable maximum 4 different machines.

Software

Flags =

  • 0=normal action and (soft flow) hall sensor beer valve
  • 1= inverted all inputs
  • 2 = inverted contact output 3 & 4
  • 4 =engolit non drip invert inputs line 3
April 24, 2006, at 02:50 PM by 81.188.94.80 -
Changed lines 18-27 from:
to:

The 6-way connector

pin 1+12V (output)
pin 2GND
pin 3NC
pin 4Network A
pin 5Earth ( shielding )
pin 6Network B
April 24, 2006, at 02:48 PM by 81.188.94.80 -
Changed lines 1-18 from:

http://wiki.etcworld.be/uploads/Main/input1.jpg

to:

Input Node or 24-4 Node

http://wiki.etcworld.be/uploads/Main/input1.jpg

INPUT-node (24/4) ''' Switches & ledís''' :

On the frontpanel youíll find :

  • A push-button switch : SERVICE-switch. This transmits the ID-number of the node.
  • A yellow led : SERVICE-led. Lights-up when you push the service-switch. When this led flashes or is lit continuously, there is a severe soft-ware problem occurred in the node. ( call us )
  • A red led : TRANSMIT-led
  • A second red led : RECEIVE-led

The 4-way connector
Not used

April 24, 2006, at 02:46 PM by 81.188.94.80 -
Added line 1:

http://wiki.etcworld.be/uploads/Main/input1.jpg

edit · history · print
Page last modified on June 08, 2010, at 09:11 AM