Flow 2000

Switches & ledís

On the front panel youíll find :

  • A push-button switch: SERVICE-switch. This transmits the ID-number of the node.
  • Yellow LED: SERVICE-led. Lights up when you push the service-switch. When this led flashes or is lit continuously, a severe software problem occurred in the node. (Call us)
  • Red LED: TRANSMIT-led
  • Red LED: RECEIVE-led

Connection :

The 6-way network connector.

pin 1+12V (output)
pin 2GND
pin 3NC
pin 4Network A
pin 5Earth ( shielding )
pin 6Network B

There are 6 12-way connectors on the bottom.

Most left 4-way connector: Transfo

pin 1hot-side first secondary
pin 2low-side first secondary
pin 3hot-side second secondary
pin 4low-side second secondary



Secondleft 4-way connector: Disconnect Beer

pin 1/
pin 2/
pin 3nc alarm contact
pin 4nc alarm contact


Third, fourth, fifth and sixth 4-Way connector: Input Flow sensor 1 to 4

pin 1+12Vpin 1 flow sensor
pin 2Pulse inpin 2 flow sensor
pin 3GND1pin 3 flow sensor
pin 4GND2pin 4 flow sensor


Flowmeters

Digmesa (pdf)
Datasheet (pdf)
Digmesa (pdf)
Datasheet (pdf)
IR-OPFLOW (pdf)
Datasheet (pdf)


Connections Digmesa
Connections
Connections Digmesa
Connections
Connections IR-Opflow
Connections


WARNING: Never use the Debitmetre Electromagnetique flowmeters in combination with other flow meters on one node!